• 1 – 20 t/h
  • 0.7 – 2 Mpa
  • Industrial
  • In Stock
  • Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
  • Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.

SA's NO 1 Induction Geyser. New!! Tankless instan

2019-9-11 · To heat a conventional 150 litre geyser from 20 deg C to 65 deg Celsius takes approximately two and a half hours and uses 7.8kw of electricity. To heat the equivalent amount of water by means of an induction geyser process will take approximately 1 hour and uses approximately 2.5kw of electricity.

Human Heat Gain - Engineering ToolB

2019-9-6 · Heat gain from persons in air conditioned spaces - in btu/hr. The values can be used to calculate heat loads that need to be handled by air conditioning systems. Typical Application lights, electric equipment, machines, evaporation from water surfaces, polluting fluids

How to Calculate The Capacity of Water Tank And

Generally water is stored either in a cylindrical tank or in a square tank. We can easily find out the capacity of water storage tank of any size in liters. For eg. if you want to find out the capacity of a square water tank measuring 1m length, 1m breadth, 1m height, first convert meter to cm. As the formula to find out the volume of cube is a^3 we can get answer as 1000,000 cc (1 m = 100 cm)

PROCESS DESIGN OF STEAM BOILERS (PROJEC

2016-3-6 · Carryover is caused by a faulty boiler water condition. Combustion Control System - The portion of a boiler control system associated with the control and maintenance of air/fuel mixtures throughout the operating range of the burner and during changes in firing rate. Contractor - Refers to the persons, firm or company whose tender has been

BOILER CLASS 2 LICENSE EXAMINATION STUDY GUI

2018-2-8 · 150 psi. Used piping- If water is used to perform the leak test, the metal temperature must be at least 60oF to assure the vessel is not thermally stressed. For personnel safety, the temperature should To calculate the inner circumference you would use the diameter of the inside of the pipe.

HYDROSTATIC PRESSURE TESTING OF PIPING (PROJEC

2014-5-17 · HYDROSTATIC PRESSURE TESTING OF PIPING (PROJECT STANDARDS AND SPECIFICATIONS) Page 5 of 19 Rev: 01 July 2011 TEST WATER CRITERIA Care shall be taken to insure the use of clean water for hydrostatic tests. And the sea water is prohibited to be used. A suitable filter should be provided in the filling line to the systems in order to

Calculating Cooling Loads - Engineering ToolB

2019-9-6 · Calculating chiller and cooling tower refrigeration - in tons. Related Topics . Air Conditioning - Air Conditioning systems - heating, cooling and dehumidification of indoor air for thermal comfort; Related Documents . Air Conditioner Efficiency - Air conditioner efficiency is the ratio between heat removed and power (watt) used - EER and SEER; Chilled Water Systems - Chilled water system

How to Determine the Required Size of a Tankless Ho

2018-12-27 · Tankless water heater efficiency is determined by the water flow rates inside your home. A low-flow shower head may use 1.5 gallons of hot water per minute, or GPM as it is called.

Section 2 START-UP AND OPERATION STEAM BOILE

START-UP AND OPERATION STEAM BOILERS POTENTIAL HAZARD TO EQUIPMENT AND TO OPERATORS OR PERSONS IN THE BUILDING. SERVICING AND START-UP MUST BE DONE ONLY BY FULLY TRAINED AND lowering the boiler water level (by opening the boiler blowdown valve for probe controls, and by

Heating_and_Air_Conditioning[1

2010-12-26 · the water is heated to 30 – 45°C in a boiler. As a rule, the inlet temperature is adjusted to the outdoor temperature. The control value from each room is needed to

How to Calculate The Capacity of Water Tank And

Generally water is stored either in a cylindrical tank or in a square tank. We can easily find out the capacity of water storage tank of any size in liters. For eg. if you want to find out the capacity of a square water tank measuring 1m length, 1m breadth, 1m height, first convert meter to cm. As the formula to find out the volume of cube is a^3 we can get answer as 1000,000 cc (1 m = 100 cm)

ModelRated steam capacity(t/h)Rated working pressure(Mpa)Rated steam temperature(℃)Maximum transport size(m)
(L×W×H)
WNS1-0.7-Y(Q)10.71703.3×1.8×2.1
WNS1-1.0-Y(Q)111843.3×1.8×2.1
WNS1.5-1.0-Y(Q) 1.511843.0×1.8×2.0
WNS1.5-1.25-Y(Q)1.51.251943.0×1.8×2.0
WNS2-1.0-Y(Q) 211844.4×2.1×2.5
WNS2-1.25-Y(Q)21.251944.4×2.1×2.5
WNS3-1.0-Y(Q)311844.6×2.3×2.6
WNS3-1.25-Y(Q)31.251944.6×2.3×2.6
WNS4-1.25-Y(Q)41.251944.7×2.5×2.9
WNS4-1.6-Y(Q)41.62044.7×2.5×2.9
WNS5-1.25-Y(Q)51.251945.3×2.7×3.3
WNS5-1.6-Y(Q)51.62045.3×2.7×3.3
WNS6-1.25-Y(Q)61.251945.9×2.6×3.0
WNS6-1.6-Y(Q)61.62045.9×2.6×3.0
WNS8-1.25-Y(Q)81.251945.9×2.8×3.1
WNS8-1.6-Y(Q)81.62045.9×2.8×3.1
WNS10-1.25-Y(Q)101.251947.7×2.8×3.1
WNS10-1.6-Y(Q)101.62047.7×2.8×3.1
WNS15-1.25-Y(Q)151.251947.0×3.1×3.6
WNS15-1.6-Y(Q)151.62047.0×3.1×3.6
WNS20-1.25-Y(Q)201.251948.3×3.4×4.0
WNS20-1.6-Y(Q)201.62048.3×3.4×4.0