• 1 – 20 t/h
  • 0.7 – 2 Mpa
  • Industrial
  • In Stock
  • Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
  • Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.

Boiler Calculations - K

2003-10-30 · Another tool used in boiler calculation is the pressure-enthalpy diagram for steam/water (figure 5). With the p-h diagram it is easy to visualize the partial shares of the total heat load on different heat exchanger surfaces in the boiler: drawing the steam heating process in the boiler onto the p-h diagram will give a horizontal line (if we

Water Treatment - lynntech.co.

2019-8-28 · Importers& marketers of premium water treatment chemicals, specialty chemicals (boiler chemicals, cooling tower chemicals, RO chemicals,), chemical cleaners, sanitizers and antiseptic disinfectants, Detergents& laboratory chemicals

Ecospec India - Boiler Water Treatment | BacComb

2018-12-28 · Boiler Water; It is controlled by micro-processor, giving consistent treatment 24 hours. This has given customers freedom from periodic chemical dosing, regular maintenance, and gave them peace that assured treatment is automatically delivered 24x7 without manual intervention.

Industry & Process Solutions | sera Gm

Since 1945 sera dosing technology with high quality dosing pumps and dosing systems is worldwide in service in various other different industries. The products create added value and provide high-quality goods for consumer s.. In the field of Industry & Process Solutions sera offers:. Customer specific dosing systems; Reliable and accurate dosing; Certification, for example according to ATEX, EAC

Drew Marine - The global leader providing technica

2019-7-17 · Drew Marine is a global leader providing technical solutions and services to the marine industry with a comprehensive line of advanced marine chemicals, and equipment.

CONDENSATE TREATMENT 9-150 25 LTR

2019-9-15 · NALFLEET™ Condensate Treatment 9-150 is a neutralising type corrosion inhibitor for the use in steam and steam condensate systems. NALFLEET™ Condensate Treatment can be used at boiler operating pressures up to 165 bar. Dosing Method NALFLEET™ Condensate Treatment 9-150 should be injected on a continuous basis.

DOSING SYSTEM MANUAL TM - MARICHEM-MARIGAS

2015-10-1 · lated to 0.3lt/ton of the boiler's water capacity on a daily basis. There after, the flow is regulated ac-cording to the test results obtained from using the WT SULFI TEST KIT. Dosing unit location: The dosing, must be done by . introducing the DOSING SYSTEMS tubing into the boiler's feed pump suction line or into the hot well,

Ecospec India - Boiler Water Treatment | BacComb

2018-12-28 · Boiler Water; It is controlled by micro-processor, giving consistent treatment 24 hours. This has given customers freedom from periodic chemical dosing, regular maintenance, and gave them peace that assured treatment is automatically delivered 24x7 without manual intervention.

Boiler Water Treatment Auto 25 Ltrs | Marine Chemica

Boiler Chemicals-42. A representative sample of boiler water should be drawn for analysis daily. The sample should always be taken from the same point after blow down, cooled and tested immediately. Follow the Spectrapak Test Kit instructions and log the results. Suitable for dosing with Rxsol Boiler Water Treatment Dosing Unit.

Presentation by S.K.SHARMA D.G.M(CHEMISTRY) NCP

2019-3-14 · • supercritical boiler oerate at pressure >203 kg/cm2 and temperature is >600 deg.c therefore the construction of have high mechanical strength and low creep. • at super critical condition the medium is just a homogeneous fluid rather than water or steam. therefore usually supercritical boiler

Chapter 35 - Chemical Feed Systems | SU

2019-9-12 · These chemicals may be fed either separately or in combination; in most balanced treatment programs, two or three chemicals are fed together. The preferred feed point varies with the chemical specified. For example, when caustic soda is used to maintain boiler water alkalinity, it is fed directly to the boiler

ModelRated steam capacity(t/h)Rated working pressure(Mpa)Rated steam temperature(℃)Maximum transport size(m)
(L×W×H)
WNS1-0.7-Y(Q)10.71703.3×1.8×2.1
WNS1-1.0-Y(Q)111843.3×1.8×2.1
WNS1.5-1.0-Y(Q) 1.511843.0×1.8×2.0
WNS1.5-1.25-Y(Q)1.51.251943.0×1.8×2.0
WNS2-1.0-Y(Q) 211844.4×2.1×2.5
WNS2-1.25-Y(Q)21.251944.4×2.1×2.5
WNS3-1.0-Y(Q)311844.6×2.3×2.6
WNS3-1.25-Y(Q)31.251944.6×2.3×2.6
WNS4-1.25-Y(Q)41.251944.7×2.5×2.9
WNS4-1.6-Y(Q)41.62044.7×2.5×2.9
WNS5-1.25-Y(Q)51.251945.3×2.7×3.3
WNS5-1.6-Y(Q)51.62045.3×2.7×3.3
WNS6-1.25-Y(Q)61.251945.9×2.6×3.0
WNS6-1.6-Y(Q)61.62045.9×2.6×3.0
WNS8-1.25-Y(Q)81.251945.9×2.8×3.1
WNS8-1.6-Y(Q)81.62045.9×2.8×3.1
WNS10-1.25-Y(Q)101.251947.7×2.8×3.1
WNS10-1.6-Y(Q)101.62047.7×2.8×3.1
WNS15-1.25-Y(Q)151.251947.0×3.1×3.6
WNS15-1.6-Y(Q)151.62047.0×3.1×3.6
WNS20-1.25-Y(Q)201.251948.3×3.4×4.0