WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.
2015-3-9 · dustand flue gas and maximum allowable emission concentration limit of sulfur dioxide for natural ventilation coal-burning boiler with a capacity<0 .7MW (1t/h), and
2017-7-17 · Energy - saving Analysis of Low Temperature Economizer in Boiler Tail Flue Your current location: Home
The Introduction of Gas/Oil Fired Steam Boiler: WNS gas & oil fired steam boiler is a kind of safe and high efficiency heating equipment from Yuanda with full automatic control system, It can also be regarded as fire tube boiler, packaged boiler, three pass design boiler and eco-friendly boiler.
Flue gas analysis is a diagnostic tool which provides the gas fitter with important information regarding the safety and efficiency of a gas appliance. All appliance standards include a maximum amount of CO which may be produced by an appliance; the most current values are included in
2018-8-5 · areas of the boiler including tubes, burner, furnace, and refractory, is available from either end of the boiler. This makes maintenance easier and reduces associated costs. The wetback boiler design has a water cooled turn around chamber used to direct the flue gases from the furnace to the tube banks. The wetback design requires less
2008-3-3 · Home » Performing a Combustion Analysis. Furnaces HVAC Residential Market Technical Performing a Combustion Analysis however, it is the result of auto exhaust from an attached garage or depressurization of the home, resulting in insufficient air for combustion. Connect flue gas sampling probe assembly to the analyzer per the
Flue gas analysis using a Nova flue gas analyzer will enable you to measure the concentrations of pollutants present and adjust burners on a boiler for optimal combustion. Nova exhaust gas analyzers are useful for environmental control, for general boiler maintenance, and also as a . boiler flue gas analyzer Industrial Boiler Supplier
2013-12-24 · the exhaust gas temperature in many thermal power plants is much higher than the designed value, thus, the recycle and reuse of the waste heat of tail flue gas is necessary. However, lower exhaust gas temperature will aggravate low tem-perature corrosion of the tail heating surface, which also causes huge economic losses.
ANALYSIS OF USING EXHAUST FLUE GAS FOR POWER 2018-4-21 · exhaust flue gas is used in the condensate system for the purp ose of pre -heating. The output obtained is same as that of the electric low pressure heater. That the heat of the exhaust gas and the heat of the electric heater is same.
2019-9-6 · Combustion air and flue gas for some common fuel gases, solids and fluids: Combustion - Boiler house topics - fuels like oil, gas, coal, wood - chimneys, safety valves, tanks Fuels Exhaust Temperatures - Exhaust and outlet temperatures for some common fuels - natural gas,
2019-9-14 · Higher heating value (HHV) 22‚900 Btu/lb. Assumptions: Loss due to CO in the flue gas is negligible.CO concentrations in the flue gas should normally be under 50 ppm by volume. A concentration of about 350 ppm CO is on the brink of violation of CCME emissions guidelines‚ and represents a loss of efficiency of about 0.11 % of fuel input.; Loss due to unburned hydrocarbons in the flue gas is
Model | Rated steam capacity(t/h) | Rated working pressure(Mpa) | Rated steam temperature(℃) | Maximum transport size(m) (L×W×H) |
WNS1-0.7-Y(Q) | 1 | 0.7 | 170 | 3.3×1.8×2.1 |
WNS1-1.0-Y(Q) | 1 | 1 | 184 | 3.3×1.8×2.1 |
WNS1.5-1.0-Y(Q) | 1.5 | 1 | 184 | 3.0×1.8×2.0 |
WNS1.5-1.25-Y(Q) | 1.5 | 1.25 | 194 | 3.0×1.8×2.0 |
WNS2-1.0-Y(Q) | 2 | 1 | 184 | 4.4×2.1×2.5 |
WNS2-1.25-Y(Q) | 2 | 1.25 | 194 | 4.4×2.1×2.5 |
WNS3-1.0-Y(Q) | 3 | 1 | 184 | 4.6×2.3×2.6 |
WNS3-1.25-Y(Q) | 3 | 1.25 | 194 | 4.6×2.3×2.6 |
WNS4-1.25-Y(Q) | 4 | 1.25 | 194 | 4.7×2.5×2.9 |
WNS4-1.6-Y(Q) | 4 | 1.6 | 204 | 4.7×2.5×2.9 |
WNS5-1.25-Y(Q) | 5 | 1.25 | 194 | 5.3×2.7×3.3 |
WNS5-1.6-Y(Q) | 5 | 1.6 | 204 | 5.3×2.7×3.3 |
WNS6-1.25-Y(Q) | 6 | 1.25 | 194 | 5.9×2.6×3.0 |
WNS6-1.6-Y(Q) | 6 | 1.6 | 204 | 5.9×2.6×3.0 |
WNS8-1.25-Y(Q) | 8 | 1.25 | 194 | 5.9×2.8×3.1 |
WNS8-1.6-Y(Q) | 8 | 1.6 | 204 | 5.9×2.8×3.1 |
WNS10-1.25-Y(Q) | 10 | 1.25 | 194 | 7.7×2.8×3.1 |
WNS10-1.6-Y(Q) | 10 | 1.6 | 204 | 7.7×2.8×3.1 |
WNS15-1.25-Y(Q) | 15 | 1.25 | 194 | 7.0×3.1×3.6 |
WNS15-1.6-Y(Q) | 15 | 1.6 | 204 | 7.0×3.1×3.6 |
WNS20-1.25-Y(Q) | 20 | 1.25 | 194 | 8.3×3.4×4.0 |
WNS20-1.6-Y(Q) | 20 | 1.6 | 204 | 8.3×3.4×4.0 |