• 1 – 20 t/h
  • 0.7 – 2 Mpa
  • Industrial
  • In Stock
  • Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
  • Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.

Improvement Power Plant Efficiency with Condense

2011-7-4 · in the condenser where 134 MW is lost to the environment while only 13 MW was lost from the boiler system. The percentage ratio of the exergy destruction to the total exergy destruction was found to be maximum in the boiler system (77%) followed by the turbine (13%), and then the forced draft fan condenser

Flue Gas Condensers | CleanBoiler.org - Boile

The water is most often used for boiler make-up water or some other need that coincides with boiler operation. There is a class of economizers that are designed to condense the flue gases and/or have the water in direct contact with flue gases. I have called them 'Flue Gas Condensers'.

What is the difference between chiller and condense

On the other hand, a chiller uses a fan to circulate the water supply. What is difference between cooler and condenser? Type your answer here the basic difference is the phase of the material

What is a Condensing Gas Boiler? | U.S. Boiler Compa

Making a wise choice about a new boiler can help you cut your home's heating bill. But, what is the difference between a condensing gas boiler and non-condensing boiler? Which boiler is most efficient? And which one is right for your home?

Rheem Ruud ECM Outdoor Condenser Fan Motor 5

Rheem Ruud ECM Outdoor Condenser Fan Motor 51-102870-03 51-102870-09. This is a brand new Original Equipment Manufacturer (OEM) Rheem Ruud WeatherKing Thermal Zone Corsaire SureComfort Protech outdoor unit condenser fan motor part# 51-102870-09. Replaces the following part #'s: 51-102870-09, 51-102870-03 This part is used in, but not limited to the following models: (On your

Steam Condenser - Definition, Working, Types an

In this steam condenser, the cooling water enters into boiler through lower half of the tubes in one direction and returns in opposite direction through the upper half as shown in the figure above. This type of condenser is used in ships as it can carry only a limited quantity of water for the boiler.

ET-Companion Condenser removes water from th

2018-9-26 · What it does. When installed with an EVAPORATIVE TANK™, the ET-Companion Condenser ™ removes water from the evaporator's air exhaust and returns it in the form of distilled water for reuse. The dry air is returned to the EVAPORATIVE TANK™ to work again.

CONDENSER FAN - Jinan Retekool Inc - page

China CONDENSER FAN catalog of 7inch to 16 Inch Auto Car A/C Condenser Fan Motor, Car Air Conditioning 12V / 24V Push Air Flow AC Motor External Air Cooling Condenser Fan provided by China manufacturer - Jinan Retekool Inc, page1.

How Does an Air Cooled Condenser Work? | SPG Dr

How Does an Air Cooled Condenser Work? An air cooled condenser (ACC) is a direct dry cooling system where steam is condensed inside air-cooled finned tubes. The cool ambient air flow outside the finned tubes is what removes heat and defines the functionality of an ACC.

Condenser (steam turbine) | Engineering | FANDO

2017-12-3 · Condenser refers here to the shell and tube heat exchanger installed at the outlet of every steam turbine in Thermal power stations of utility companies generally. These condensers are heat exchangers which convert steam from its gaseous to its liquid state, also known as

Fan Blades, buy condenser fan blades at AC Unit Part

Bard Condenser Fan Blade 5151-060 5151-027 S5151-027 This is a brand new Original Equipment Manufacturer (OEM) Bard condenser fan blade 24" diameter 28 degree 5-blade CCW rotation, part# 5151-060 (also part# S5151-060).

ModelRated steam capacity(t/h)Rated working pressure(Mpa)Rated steam temperature(℃)Maximum transport size(m)
(L×W×H)
WNS1-0.7-Y(Q)10.71703.3×1.8×2.1
WNS1-1.0-Y(Q)111843.3×1.8×2.1
WNS1.5-1.0-Y(Q) 1.511843.0×1.8×2.0
WNS1.5-1.25-Y(Q)1.51.251943.0×1.8×2.0
WNS2-1.0-Y(Q) 211844.4×2.1×2.5
WNS2-1.25-Y(Q)21.251944.4×2.1×2.5
WNS3-1.0-Y(Q)311844.6×2.3×2.6
WNS3-1.25-Y(Q)31.251944.6×2.3×2.6
WNS4-1.25-Y(Q)41.251944.7×2.5×2.9
WNS4-1.6-Y(Q)41.62044.7×2.5×2.9
WNS5-1.25-Y(Q)51.251945.3×2.7×3.3
WNS5-1.6-Y(Q)51.62045.3×2.7×3.3
WNS6-1.25-Y(Q)61.251945.9×2.6×3.0
WNS6-1.6-Y(Q)61.62045.9×2.6×3.0
WNS8-1.25-Y(Q)81.251945.9×2.8×3.1
WNS8-1.6-Y(Q)81.62045.9×2.8×3.1
WNS10-1.25-Y(Q)101.251947.7×2.8×3.1
WNS10-1.6-Y(Q)101.62047.7×2.8×3.1
WNS15-1.25-Y(Q)151.251947.0×3.1×3.6
WNS15-1.6-Y(Q)151.62047.0×3.1×3.6
WNS20-1.25-Y(Q)201.251948.3×3.4×4.0
WNS20-1.6-Y(Q)201.62048.3×3.4×4.0