• 1 – 20 t/h
  • 0.7 – 2 Mpa
  • Industrial
  • In Stock
  • Nature gas, coke oven gas, biogas, methanol, liquid propane gas, diesel, heavy oil, light oil, crude oil, etc.
  • Heat supplying, chemical, food, textile, printing and dyeing, cigarettes and tobacco, fodder, pharmacy, building materials, brewery, rubber, hospital etc.

WSN series gas / oil fired industrial horizontal steam boiler is a kind of safety and high efficiency heating equipment with fully automatic intelligent control system. It’s a boiler shell type 3 passes wetback oil/gas fired boiler. Usually, the WNS series steam boilers widely used for industry production and processing, such as textile mill, medicine industry, food & beverage industry, chemical industry, garment industry, food processing industry, and wood processing industry, moreover, it could be used for central heating in enterprise, hotel, hospital, civil architecture, etc.

Series Q35 MIZER Automatic Vent Damper Syste

2001-4-2 · 2 Q Series Q35 MIZER Automatic Vent Damper System Technical Bulletin CAUTION: Equipment Damage. The following restrictions apply to the Q35 MIZER damper system. • Must not be used on Liquefied Petroleum (LP) gas applications. • Must not be used with gas valves that can be manually opened. • Must be used in conjunction with an intermittent pilot or direct

Damper Actuator, Damper Actuator direct from Hebe

Damper Actuator from Hebei Chunfeng Heating Equipment Co., Ltd.. Search High Quality Damper Actuator Manufacturing and Exporting supplier on Alibaba.com.

Draft Damper Assembly || Boiler Controls || Preferre

The Model E-Link Draft Damper Assembly pre-mounts a Model SM-15 servo actuator and JC-22XMTR Draft Range Transmitter Assembly. Only a stack draft connection is required. The Model E-Link Draft Damper Assembly is part of a full scope control package that assures safe and efficient control with undivided system responsibility.

Pneumatic Damper Actuators | Industrial Contro

2019-9-1 · The D-3062 Pneumatic Piston Damper Actuator accurately positions small dampers on Variable Air Volume (VAV) and terminal units. The actuator is also recommended for use on other air flow control dampers in interiors with a maximum area of 4 ft2

Solenoid Actuator - FurnaceCompare.c

The actuator is de-energized once the damper is open and remains idle until the correct temperature has been reached. Upon reaching the necessary temperature, the operation repeats to close the damper. The actuator again remains idle until the next heating cycle. How to Buy a Replacement Solenoid Actuator

Oxygen Control | CleanBoiler.o

An electronic sensor is inserted into the boiler flue, near the boiler, ahead of any dampers or other sources of air leakage into the boiler or flue. The sensor is connected to a control panel that measures oxygen and sends a signal to a control damper on the burner air supply. From the Hays Cleveland OXY-MIZER™ data sheet:

Steam Boiler Damper Actuator - casapepa1.

damper in steam boiler – Industrial Boiler Supplier. 2017-12-22 · Boiler Valve and Damper Actuator Control steam control or water control applications in the boiler. Superheater – Wikipedia Damper and snifting valve. The steam passing through the if one opens saturated steam from the boiler to the superheater it goes straight through

damper boiler - pearlresort.co.

damper in steam boiler – Industrial Boiler Supplier. 2017-12-22 · Damper Regulator For Steam Boiler – ChestofBooks.com The damper regulator used on a steam boiler is a simple device that automatically controls the draft dampers by reason of the changing pressures of the steam. The

damper in steam boiler – Industrial Boiler Suppli

2017-12-22 · In Boilers, it may be used to maintain furnace pressure by controlli Increasing Steam Boiler Efficiency with a Vent (Flue) Damper Fitting a flue damper is an excellent way to improve the efficiency of your boiler. gas boiler no heat call bad vent damper – YouTube bad gas boiler vent damper This feature is not available right now.

Automatic Vent Damper System | Gas Heat Flu

2019-9-6 · Automatic Vent Damper System | Gas Heat Flue Economizer. The automatic vent damper adds efficiency to water heaters and furnaces. The automatic flue damper traps heat in the furnace, boiler, or water heater. It holds heat in and around the heat exchanger instead of

The flue damper product range - kutzner-weber.

2007-10-29 · Thermal flue damper This attractive and simple design is used exclusively with gas-fired appliances. Without flue damper The warm room air is drawn through the stove and flow preventer through the chimney. While this is happening, the energy stored in the stove also escapes by the cooling effect of the air. With flue damper The draw from the

ModelRated steam capacity(t/h)Rated working pressure(Mpa)Rated steam temperature(℃)Maximum transport size(m)
(L×W×H)
WNS1-0.7-Y(Q)10.71703.3×1.8×2.1
WNS1-1.0-Y(Q)111843.3×1.8×2.1
WNS1.5-1.0-Y(Q) 1.511843.0×1.8×2.0
WNS1.5-1.25-Y(Q)1.51.251943.0×1.8×2.0
WNS2-1.0-Y(Q) 211844.4×2.1×2.5
WNS2-1.25-Y(Q)21.251944.4×2.1×2.5
WNS3-1.0-Y(Q)311844.6×2.3×2.6
WNS3-1.25-Y(Q)31.251944.6×2.3×2.6
WNS4-1.25-Y(Q)41.251944.7×2.5×2.9
WNS4-1.6-Y(Q)41.62044.7×2.5×2.9
WNS5-1.25-Y(Q)51.251945.3×2.7×3.3
WNS5-1.6-Y(Q)51.62045.3×2.7×3.3
WNS6-1.25-Y(Q)61.251945.9×2.6×3.0
WNS6-1.6-Y(Q)61.62045.9×2.6×3.0
WNS8-1.25-Y(Q)81.251945.9×2.8×3.1
WNS8-1.6-Y(Q)81.62045.9×2.8×3.1
WNS10-1.25-Y(Q)101.251947.7×2.8×3.1
WNS10-1.6-Y(Q)101.62047.7×2.8×3.1
WNS15-1.25-Y(Q)151.251947.0×3.1×3.6
WNS15-1.6-Y(Q)151.62047.0×3.1×3.6
WNS20-1.25-Y(Q)201.251948.3×3.4×4.0
WNS20-1.6-Y(Q)201.62048.3×3.4×4.0